DISPOSABLE FORMWORK FOR VENTILATED SUBFLOOR
HEIGHT FROM 56 CM TO 300 CM
*Referred to the dome only.
Atlantis Tank – H 56 / H 300 cm
Working dimensions
cm
50 x 50
Dome height
cm
16
Leg height
cm
from 40 to 284
Quantity of concrete to the crown
m3/m2
view formula
Pallet dimensions*
cm
110 x 110 x 250 h
Sq.mt. per pallet*
m2/PAL
75
Pieces per pallet*
pz./PAL
300
Pallet weight
Kg./PAL
510
The product is not affected if weathered.
Formula to calculate concrete consumption VCLC = concrete volume in m3/m2
The formula considers the higher volume of concrete due to natural deflection of the formwork.Ø 11 cm | VCLS = h/100 + 0,028 + 0,037 x H/100
h = height of upper slab in cm
H = total height of Atlantis system, before concrete casting, in cm
*Referred to the dome only.
Atlantis Tank L 100×100 – H 56 / H 300 cm
Working dimensions
cm
100 x 100
Dome height
cm
12
Leg height
cm
from 44 to 288
Quantity of concrete to the crown
m3/m2
view formula
Pallet dimensions*
cm
110 x 110 x 250 h
Sq.mt. per pallet*
m2/PAL
70
Pieces per pallet*
pz./PAL
70
Pallet weight
Kg./PAL
740
The product is not affected if weathered.
Formula to calculate concrete consumption VCLC = concrete volume in m3/m2
The formula considers the higher volume of concrete due to natural deflection of the formwork.Ø 11 cm | VCLS = h/100 + 0,0330 + 0,0090 x H/100
Ø 16 cm | VCLS = h/100 + 0,0316 + 0,0194 x H/100
h = height of upper slab in cm
H = total height of Atlantis system, before concrete casting, in cm
Atlantis System installation method.